10,000 Watt Automatic Standby System - Starts automatically when your power fails and transfers your electrical loads to generator power. When utility power returns, the system transfers back to utility power and shuts off the generator.
Includes weather protective enclosure, composite mounting pad (for easier installation), flexible fuel line connector to your propane/natural gas pipe, automatic transfer switch with pre-wired 10 circuit load center and step-step installation guide with colored photographs.
Protect the things that matter most...with an automatic system.
This 10,000 watt generator features a 18 HP OHVI 530cc propane or natural gas engine, spin-on oil filter, low oil pressure shutdown, high water temperature shutdown, automatic voltage regulation, enclosed muffler, timed battery trickle charger and automatic 100 amp transfer switch with seven day exerciser, pre-wired conduits and built-in load center.
Generator
Automatic Voltage Regulator
Standard
Main Line Circuit Breaker
35 Amps
Power Single-Phase
---
Maximum Output
10,000 watts
Continous Output
9,000 watts
Load Amperage at 120 volts
---
Maximum Load
83 Amps
Continous Load
75 Amps
Load Amperage at 240 volts
---
Maximum Load
41.5 Amps
Continous Load
37.5 Amps
Sound Level @ 23 ft(7 m) at full load
63 dB(A)
Engine
Type
OHVI 530cc
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Power
18 HP
Cylinders
2
Electronic Governor
Standard
Oil Capacity w/ Filter
Approx. 1.7 Qts
Battery Requirement (Not Included)
12 VDC 350 CCA
Fuel
Propane or Natural Gas
Cooling System
Air-cooled
Starting System
Electric
Consumption
Consumption at 1/2 load - cu.ft./hr (gal/hr)
46 (1.25)
Consumption at 3/4 load - cu.ft./hr (gal/hr)
62 (1.68)
Consumption at full load - cu.ft./hr (gal/hr)
70 (1.93)
Transfer Switch
Current Rating (Amps)
100
Voltage Rating (VAC)
250
Weekly Exercise
Standard
UL Listed
Standard
Pre-Wired Circuits
MLS4-Y
15 Amp 120 V
5
20 Amp 120 V
3
20 Amp 240
1
30 Amp 240
1
Dimensions
MLS4-Y
Height
26.5"
Width
12.5"
Depth
7"
Controls
Engine Warm-Up
Standard
Engine Cool-Down
Standard
Battery Trickle Charger
Standard
Low Oil Pressure Shutdown
Standard
High Temperature Shutdown
Standard
Overspeed Shutdown
Standard
Overcrank Protection
Standard
Installation Data
Fuel Inlet Fitting
3/4" FNPT
Fuel Inlet Pressure
Nat. Gas: 5-7" Propane: 11-14"
Recommended Hose Size
3/8"
BTU Content
130,000 BTU
Flexible Fuel Line
1'-3/4" NPT Fitting
Recommended Clearances
5' - All Sides
Composite Mounting Pad
Standard
No. of Conductors
4
Wire Size of Conductors
No. 4 AWG
Length of Pre-Wired Cord from Genset to External Connect Box
55"
External Connect Box (L x D x W)
9-1/4" x 2" x 5"
Service Side (Facing fuel inlet)
Left-Side
Exhaust Location & Direction (Facing service side)